Q-Eye Radar
Stationary non-contact flow meter
Technical specifications
- Sensor:
1 x velocity
1 x water level (external 4-20 mA sensor) - Frequency: 24 GHz
- Beam Width: 11° at -3dB
- Range: ± 0.05 m/s, to ± 15 m/s
- Resolution: 1 mm/s; min. wave height 3 mm
- Display: 4 lines, 20 characters
- Keyboard: 4 keys
- Data logger: 16 GB MicroSD card
- Communication: RS-485, Modbus (RS-232 or RS-485), Wireless LAN, 4G (LTE) / 3G (HSPA+) / 2G, Ethernet 10/100 Mbps
- Inputs: max. 4 x 4-20 mA, 2 x digital
- Outputs: max. 4 x 4-20 mA, 4 x relay, 2 x pulse
- Power supply: 9-36 V DC or 100-240 V AC (50/60 Hz)
- Protection class housing: IP66 (NEMA 4)
- Enclosure: Aluminum, wall mounted
DOWNLOADS
Related products

Kanalis
Time of flight system with digital signal processing
Technical specifications
- Acoustic paths: 1 to 10 (more upon request)
- Channel width: 1 to 20 m
- Accuracy: ± 2 % (typical, depending on number of installed paths)
- Display: 4 lines, 20 characters
- Data logger: 16 GB MicroSD card
- Communication: RS-485, Modbus RTU/TCP, Wireless LAN, Ethernet 10/100 Mbps, 4G (LTE) / 3G (HSPA+) / 2G
- Inputs: max. 4 x 4-20 mA, 2 x digital
- Outputs: max. 4 x 4-20 mA, 4 x relay, 2 x digital
- Power supply: 9-36 V DC or 100-240 V AC (50/60 Hz)
- Protection class: IP65 (NEMA 4)
- Enclosure: ABS, wall mounted
DOWNLOADS

Transducers
Technical specifications
- Frequency: 200 kHz
- Typical channel width: 5 m
- Dimensions: Ø 140 mm, height 70 mm

Q-Eye PSC
Stationary area velocity flow meter for partially filled or pressurized pipes and open channels. Advanced Pulse-Coherent cross-correlation technology for capturing entire velocity profiles.
Technical specifications
- Sensors:
Ultrasonic velocity sensor (up to 3 sensors possible)
Water level sensors (hydrostatic, ultrasonic or radar) - Number of measurement cells: up to 32
- Velocity range: ± 5.3 m/s
- Typical accuracy flow: ± 2 % of reading, depending on site conditions
- Display: 4 lines, 20 characters
- Keyboard: 4 keys
- Data logger: 16 GB MicroSD card
- Communication: RS-485, Modbus (RS-232 or RS-485), Wireless LAN, 4G (LTE) / 3G (HSPA+) / 2G, Ethernet 10/100 Mbps
- Inputs: max. 4 x 4-20 mA, 2 x digital
- Outputs: max. 4 x 4-20 mA, 4 x relay, 2 x pulse
- Power supply: 9-36 V DC or 100-240 V AC (50/60 Hz)
- Protection class housing: IP66 (NEMA 4)
- Enclosure: Aluminum, wall mounted
DOWNLOADS

Area velocity sensor
The submersible area velocity sensor uses advanced Pulse-Coherent cross-correlation technology. The velocity profile of the entire cross-section is captured in up to 32 measurement cells, providing best-in-class resolution of flow. The sensor measures both flow velocity and water level in order to calculate total flow volume. The integrated temperature sensor is used for automatic data correction and provides enhanced statistical information, e.g. for infiltration studies.
With its dimensions of only 19 x 24 x 129 mm, the area velocity sensor causes no interference in the flow profile, which results in more accurate velocity measurements, especially in low-flow situations.
Technical specifications
- Measures flow velocity, water level and temperature
- Frequency: 1 MHz
- Range:
‒ Velocity ± 5.0 m/s
‒ Water level 0.04-1.3 m,
expandable with external 4-20 mA level sensor
‒ Temperature: -60 °C to +150 °C (linearized: 0°C to +60°C) - Accuracy:
‒ Velocity: ± 0.03 m/s from -1.5 m/s to +1.5 m/s
±2 % of reading from -5.0 bis -1.5 m/s and +1.5 bis +5.0 m/s
‒ Level: ± 2 mm
‒ Flow: Typically ± 2 %, depending on site conditions
‒ Temperature: ± 0.5 K for 4 °C to 57 °C - Min. particle concentration: > 50 ppm
- Operating temperature: -15 °C to +50 °C (non-freezing)
- Material: Stainless steel (1.4571, AISI 316 Ti), PEEK (piezo cover)
- Protection class: IP68 (48 h at 50 kPa, NEMA 6P)
- Approval: ATEX Zone 1; II 2G EEx e ib IIB T (option for stationary Q-Eye PSC)
- Dimensions: 129 x 24 x 19 mm (L including cable connector x W x H)
Related products

RV11 radar velocity sensor
Bi-directional non-contact velocity measurement. Inclusive ball-joint mount for quick and easy installation.
Technical specifications
- Frequency: 24 GHz
- Beam width: 11° (-3dB)
- Range: ± 0.05 m/s to ± 15 m/s
- Resolution: 1 mm/s, min. wave height 3 mm
- Uncertainty velocity: ± 0.5 % of reading ± 0.01 m/s
- Uncertainty flow: Typically < 5 % of reading, depending on site conditions
- Min. distance to surface 0.2 m
- Max. distance to surface 10 m
- Protection class: IP68 (48 h at 50 kPa, NEMA 6P)
- Operating temperature: – 40 °C to + 85 °C
- Dimensions: 242 mm (L mounting), 100 x 100 mm (W x H sensor)