Ductus M

Time of flight system with digital signal processing

Technical specifications
  1. Acoustic paths: 1 to 8
  2. Accuracy: up to ± 0.5 % (8 paths)
  3. Range: 0 to ± 20 m/s (bidirectional)
  4. Pipe diameter: > 3000 mm
  5. Display: 4 lines, 20 characters
  6. Windows 10 operating system
  7. Configuration and parameter setup with integrated software package
  8. Data logger: internal, sampling interval user selectable
  9. Interfaces: VGA (1024*768), PS/2 for external mouse, keyboard, 4x USB, 2x RJ-45
  10. Communication: 2 x RS-232, FTP, Modbus TCP (optional)
  11. Inputs: max. 8 x 4-20 mA
  12. Outputs: max. 4 x 4-20 mA, 2 x relay, 2 x pulse
  13. Power supply: 24 V DC
  14. Battery backup: integrated, 2 Ah
  15. Protection Class: IP65 (NEMA 4)
  16. Enclosure: powder-coated sheet steel, wall mounted
DOWNLOADS

Transducers

CO-L
Technical specifications
  1. Pipe Diameter: 0.4 m to 15 m
  2. Pipe wall thickness: up to 100 mm (steel, plastic, glass fiber)
  3. Accuracy velocity: up to ± 0.5 % of reading
  4. Frequency: 200 kHz
  5. Beam width: 8° (-3dB)
  6. Material: stainless steel, polyamide
  7. Operating temperature: -20 °C to +60 °C
  8. Dimensions: 270 x 115 x 100 mm (L x W x H)
  9. Installation: from the outside of the pipe