Transducers

CO-L
Technical specifications
  1. Pipe Diameter: 0.4 m to 15 m
  2. Pipe wall thickness: up to 100 mm (steel, plastic, glass fiber)
  3. Accuracy velocity: up to ± 0.5 % of reading
  4. Frequency: 200 kHz
  5. Beam width: 8° (-3dB)
  6. Material: stainless steel, polyamide
  7. Operating temperature: -20 °C to +60 °C
  8. Dimensions: 270 x 115 x 100 mm (L x W x H)
  9. Installation: from the outside of the pipe

Ductus

Time of flight system with digital signal processing

Technical specifications
  1. Acoustic paths: 1 to 10 (more upon request)
  2. Range: ± 20 m/s (bidirectional)
  3. Accuracy Q: up to ± 0.15 % (10 paths)
  4. Repeatability: < ± 0.02 %
  5. Zero Stability: < 1 mm/s
  6. Communication: RS-485, Modbus RTU/TCP, Wireless LAN, Ethernet 10/100 Mbps, 4G (LTE) / 3G (HSPA+) / 2G
  7. Inputs: max. 4 x 4-20 mA, 2 x digital
  8. Outputs: max. 4 x 4-20 mA, 4 x relay, 2 x pulse
  9. Power supply: 9-36 V DC or 100-240 V AC (50/60 Hz)
  10. Approval: IP66 (NEMA 4)
  11. Enclosure: aluminium
DOWNLOADS

Transducers

CO-S
Technical specifications
  1. Pipe diameter: 0.025 m to 1 m
  2. Pipe wall thickness: up to 25 mm
  3. Accuracy velocity: up to ± 0.5 % of reading
  4. Frequency: 1 MHz
  5. Beam Width: 5°
  6. Material: zinc alloy
  7. Operating temperature: -20 °C to +60 °C
  8. Dimensions: 56 x 30 x 25 mm (L x W x H)
  9. Installation: from the outside of the pipe