Transducers
TD-IM
Technical specifications
- Frequency: 200 kHz
- Beam Width: 18° (-3dB)
- Configuration: IEC41 / ASME PTC 18
- Pipe diameter: 1.0 m to 10 m
- Mounting: –
- Pressure rate: 60 bar *
- Material: stainless steel / polyamide
- Cable: twisted pair with shield
- Operating temperature: 0 °C to 40 °C
- Dimensions: 320 x 100 x 70 mm (L x W x H)
- Installation: from the inside
*) other ranges upon request

Ductus
Time of flight system with digital signal processing
Technical specifications
- Acoustic paths: 1 to 10 (more upon request)
- Range: ± 20 m/s (bidirectional)
- Accuracy Q: up to ± 0.15 % (10 paths)
- Repeatability: < ± 0.02 %
- Zero Stability: < 1 mm/s
- Communication: RS-485, Modbus RTU/TCP, Wireless LAN, Ethernet 10/100 Mbps, 4G (LTE) / 3G (HSPA+) / 2G
- Inputs: max. 4 x 4-20 mA, 2 x digital
- Outputs: max. 4 x 4-20 mA, 4 x relay, 2 x pulse
- Power supply: 9-36 V DC or 100-240 V AC (50/60 Hz)
- Approval: IP66 (NEMA 4)
- Enclosure: aluminium