
Ultrasonic flow meter
SONICO® EDGE
Properties
- Minimal pressure loss < 0.09 bar
- U0/D0, no need for flow conditioners
- Pressure ratings up to PN 16
- Medium temperature range 0.1 °C to + 50 °C
- Degree of protection IP68
- Tamper-proof
- IR interface for firmware update, parameter setting and data readout
- Integrated data logger incl. min./max. values
- Integrated medium temperature measurement
- Air detection
- External power supply
- Individual NFC communication slots with easy access plug & play modules
- Mode 5 and mode 7 data encryption
- Approved automatic detection of the direction of flow according to WELMEC 7.2 European Legal Metrology
- Approved firmware update procedure according to WELMEC 7.2 European Legal Metrology
Applications
- Water measurement, e.g. drinking water or utility water (reservoirs, pumping stations, etc.)
- Suitable for difficult installation conditions such as placement directly before or after 90° elbows, valves or pumps
- The time reverse acoustic principle enables a new level of measuring repeatability unaffected by flow perturbations, electroma- gnetic or grounding interference and water conductivity
DOWNLOADS
- sonico® EDGE Datasheet
- Pulse Module Datasheet
- 4 -20 mA Module Datasheet
- ECO Module Datasheet
- sonico® «Just brilliant» Brochure
- EU Declaration of Conformity MID
LINKS

Ductus M
Time of flight system with digital signal processing
Technical specifications
- Acoustic paths: 1 to 8
- Accuracy: up to ± 0.5 % (8 paths)
- Range: 0 to ± 20 m/s (bidirectional)
- Pipe diameter: > 3000 mm
- Display: 4 lines, 20 characters
- Windows 10 operating system
- Configuration and parameter setup with integrated software package
- Data logger: internal, sampling interval user selectable
- Interfaces: VGA (1024*768), PS/2 for external mouse, keyboard, 4x USB, 2x RJ-45
- Communication: 2 x RS-232, FTP, Modbus TCP (optional)
- Inputs: max. 8 x 4-20 mA
- Outputs: max. 4 x 4-20 mA, 2 x relay, 2 x pulse
- Power supply: 24 V DC
- Battery backup: integrated, 2 Ah
- Protection Class: IP65 (NEMA 4)
- Enclosure: powder-coated sheet steel, wall mounted
DOWNLOADS

Transducers
FT-L1000
Technical specifications
- Frequency: 1 MHz
- Beam width: 10° (-3dB)
- Configuration: IEC41 / ASME PTC 18
- Pipe diameter: 0.3 m to 5 m
- Mounting: welding socket or thread
- Pressure rate: 60 bar *
- Material: stainless steel
- Cable: twisted pair with shield
- Operating temperature: 0° to 40°C
- Dimensions: Ø 1 1/2″, Length: 186 mm
- Installation: removal of the transducer for repair, replacement or cleaning by means of a special jacking tool.
*) other ranges upon request

Transducers
CO-L
Technical specifications
- Pipe Diameter: 0.4 m to 15 m
- Pipe wall thickness: up to 100 mm (steel, plastic, glass fiber)
- Accuracy velocity: up to ± 0.5 % of reading
- Frequency: 200 kHz
- Beam width: 8° (-3dB)
- Material: stainless steel, polyamide
- Operating temperature: -20 °C to +60 °C
- Dimensions: 270 x 115 x 100 mm (L x W x H)
- Installation: from the outside of the pipe

Ductus S
Time of flight system with digital signal processing
Technical specifications
- Acoustic paths: 1 to 10 (more upon request)
- Range: ± 20 m/s (bidirectional)
- Accuracy Q: up to ± 0.15 % (10 paths)
- Repeatability: < ± 0.02 %
- Zero Stability: < 1 mm/s
- Communication: RS-485, Modbus RTU/TCP, Wireless LAN, Ethernet 10/100 Mbps, 4G (LTE) / 3G (HSPA+) / 2G
- Inputs: max. 4 x 4-20 mA, 2 x digital
- Outputs: max. 4 x 4-20 mA, 4 x relay, 2 x pulse
- Power supply: 9-36 V DC or 100-240 V AC (50/60 Hz)
- Approval: IP65 (NEMA 4)
- Enclosure: ABS, wall mounted
DOWNLOADS

Transducers
FT-S
Technical specifications
- Frequency: 1 MHz
- Beam width: 5° (-3dB)
- Configuration: IEC41 / ASME PTC 18
- Pipe diameter: 0.1 m to 2 m
- Mounting: welding socket or thread
- Pressure rate: 20 bar *
- Material: Stainless steel
- Cable: twisted pair with shield
- Operating temperature: 0° to +40°C (up to + 150 °C on request)
- Dimensions: Ø 1″, length: 293 mm
- Installation: incl. fixing device, ball valve and welding socket.
Pipe needs to be dewatered only for the time of initial installation. Designed to allow removal of the entire transducer for repair, replacement or cleaning without the need to dewater the pipe lation.
*) other ranges upon request

Transducers
CO-S
Technical specifications
- Pipe diameter: 0.025 m to 1 m
- Pipe wall thickness: up to 25 mm
- Accuracy velocity: up to ± 0.5 % of reading
- Frequency: 1 MHz
- Beam Width: 5°
- Material: zinc alloy
- Operating temperature: -20 °C to +60 °C
- Dimensions: 56 x 30 x 25 mm (L x W x H)
- Installation: from the outside of the pipe

KATflow 100
Stationary Clamp-On ultrasonic flow meter
Specification
- Pipe diameter range 10 mm to 3000 mm
- Temperature range for sensors -30 °C to +80 °C (-22 °F to +176 °F)
- Weight 750 g
- Robust IP 66 aluminium enclosure
- Sturdy unit with LCD display and five-key keypad
- Wall or pipe mounted
Features
- Low cost of ownership
- Process outputs including RS 485, Modbus RTU and HART* compatible output
- PT100 inputs for heat quantity (thermal energy) measurement
- Bi-directional measurement with totaliser function
- Innovative installation wizard for quick and intuitive programming
- Configuration can be changed to suit customer requirements
Applications
- Water and wastewater measurements
- Replacement of electromagnetic flow meters
- Monitoring and controlling of Heating, Ventilation and Air Conditioning (HVAC) systems
- Cost-effective solution for large scale projects
- Automated process control
- Shipping applications