Transducers
FT-L1000
Technical specifications
- Frequency: 1 MHz
- Beam width: 10° (-3dB)
- Configuration: IEC41 / ASME PTC 18
- Pipe diameter: 0.3 m to 5 m
- Mounting: welding socket or thread
- Pressure rate: 60 bar *
- Material: stainless steel
- Cable: twisted pair with shield
- Operating temperature: 0° to 40°C
- Dimensions: Ø 1 1/2″, Length: 186 mm
- Installation: removal of the transducer for repair, replacement or cleaning by means of a special jacking tool.
*) other ranges upon request

Ductus
Time of flight system with digital signal processing
Technical specifications
- Acoustic paths: 1 to 10 (more upon request)
- Range: ± 20 m/s (bidirectional)
- Accuracy Q: up to ± 0.15 % (10 paths)
- Repeatability: < ± 0.02 %
- Zero Stability: < 1 mm/s
- Communication: RS-485, Modbus RTU/TCP, Wireless LAN, Ethernet 10/100 Mbps, 4G (LTE) / 3G (HSPA+) / 2G
- Inputs: max. 4 x 4-20 mA, 2 x digital
- Outputs: max. 4 x 4-20 mA, 4 x relay, 2 x pulse
- Power supply: 9-36 V DC or 100-240 V AC (50/60 Hz)
- Approval: IP66 (NEMA 4)
- Enclosure: aluminium